Aopec 12v Dual Battery Monitor Management System 250A Motor Home Marine
Availability: In Stock
Add to Compare
You will need to pick up all Western Australia freights from the depot.
Aopec 12v Dual Battery Monitor Management System 250A Motor Home Marine
This unit enables you to monitor your start battery voltage and total battery activity of your auxiliary battery. We all know it is essential to monitor your starter battery and use an isolator to prevent it from being overly discharged, but it is also extremely important to know what exactly is happening with your "house power" system. This is valid for boats, 4WDs, caravans/RV's etc., especially when running inverters and refrigeration. This fantastic dual battery monitor serves that purpose by giving you the voltage of your start battery and house battery, as well as the current flow on your house battery - both charging and discharging. To top it off, the unit warns you via a buzzer if house battery falls below 11.5V (or over 15.5V). The display unit easily fits timber bulkheads up to 27mm thick, or sheet metal dashboards, and a 250A current shunt (75mV) is supplied which should suffice for all but the biggest installations. This product may save you a fortune from replacing damaged batteries.
- Front panel dimensions: 72(W) x 65(H)mm
- Mounting hole: 2" or 52mm
- Shunt dimensions: 135(L) x 30(W) x 25(H)mm
Display Function
When the engine is started, this 12V dual battery voltage and current meter begins to work. You may read voltage information of main and auxiliary batteries, you may also read voltage and current information of auxiliary battery by switching the LCD window.
Current Function
This 12V dual battery voltage and current meter can sense the direction of current. When the battery is being charged, there is a plus sign appearing before the value of current. When the battery is being discharged, there is a minus sign appearing before the value of current. And this current direction indicating function will be working all the time.
Alert Function
This 12V dual battery voltage and current meter has a function for the emergency situation. When the auxiliary batteries’ voltage is lower than 11.5V or higher than 15.5V, the buzzer will work for alerting. You can turn off the alerting by pressing the button which there is a buzzer symbol on it. When the alerting function is turned off, the clock symbol will disappear.
Since our inception in 2002, the Pinnacle Wholesalers team has sold thousands of items to happy customer & is constantly working towards being one of eBays leading customer service sellers. We are dedicated to supporting all of our customers making sure you are happy with your purchase. We want to make sure you receive quality products at the best prices, delivered on time every time.
Pinnacle Wholesalers are open 5 days a week, with a service phone number should you have any reason to phone us.
What we do not cover…
The warranty does not cover damage caused by accident, misuse, neglect, natural disaster and other external causes or to damage caused by operating the equipment in a manner outside that described in the instructions. All items need to be maintained and serviced as specified in the owner’s manual. The warranty does not replace parts that are considered to be normal wear consumables such as batteries and alike
Some of our items sell with different freight costs. Just enter your postcode into the Postage Calculator on bottom of most listings to find out the cost to your area.
Items are generally dispatched within 1-3 business days after payment is cleared however please allow approximately 7- 14 business days for it to arrive. Buyers will be able to trace the delivery online with a tracking number.
Buyers have the full responsibility to provide us with the correct delivery address and mobile phone number on the ebays checkout page before payment. We advise you contact the Courier providers (not Australia Post) prior to the delivery day.
Any changes to address after checkout will not be considered as valid. Pinnacle Wholesalers is not liable for any delay, losses and/or damage of items due to changes of delivery address after checkout, or mistakes made by buyers. Where goods are sent through Australia Post, the buyer may receive a card in their letterbox indicating their item is available for pickup from their local post office.
Re-delivery fee will be charged to buyers for items that are undeliverable and/or returned to Pinnacle Wholesalers due to incorrect delivery address or unsuccessful delivery.
Items will only be delivered during normal business hours (8am to 3.30pm) on weekdays. Delivery is not available on weekends, public holidays or after business hours. Items are also available for pick up at our warehouse. 42 Gregory street west (Off ring Rd) Lake gardens, Ballarat Victoria
Our office hours are 8am - 3.30pm. Please email us on admin@pinnaclewholesalers.net.au for a reply within 24-48 business day hours.
Write a review
Your Name:Your Review: Note: HTML is not translated!
Rating: Bad Good
Enter the code in the box below:
Insurance shipping rates for this item
Delivery times
Insurance covers damages and loss of item(s). We strongly recommend all is customers take out freight insurance.
Insurance cost as follow
(Estimate time only, please allow up to 14 days for delivery)